Facility maintenance in Washington
Washington inspects every elevator each year, sets boiler cycles by type and now holds large buildings to an energy performance standard.
Washington at a glance
- 2,549Public schoolsStatewide
- 340School districtsStatewide
- 42Public collegesStatewide
- 50,000sq ftTier 1 thresholdStatewide
- 132.0daysFreezing lowsSpokane area
- 45.4inNormal snowfallSpokane area
What Washington's climate does to buildings
Washington's climate splits at the Cascades. East of the mountains, Spokane's normals show a long freezing season, real snow and little rain.
Spokane and eastern Washington
Heating dominates in Spokane
Spokane's normal year has 6,463 heating degree days and just 515 cooling. Boilers, furnaces and heat pumps carry the load, so service them every fall.
A long freezing season
Lows reach 32°F or below on 132.0 days in a normal Spokane year. Protect outdoor valves, sprinkler lines and exposed piping from October onward.
Snow, but little rain
Normal snowfall is 45.4 inches, while total precipitation is only 16.45 inches. Plan for snow loads and ice dams more than for heavy rain.
Short bursts of heat
Spokane still averages 20.8 days a year at 90°F or more. Check rooftop units and cooling for server and electrical rooms before July.
A maintenance year in Washington
- JanCheck roofs for snow load and ice dams
- FebBook boiler inspections due before summer
- MarReport building condition scores to the board by April 1
- AprGather energy data for Clean Buildings benchmarking
- MayService rooftop units before the first 90°F days
- JunUpdate the operations and maintenance program
- JulWatch cooling in server and electrical rooms
- AugSchedule yearly elevator inspections and tests
- SepTest boiler controls and low-water cutoffs
- OctStart heating plants and wrap outdoor piping
- NovLine up snow removal and roof raking
- DecMap next year's boiler cycles by type
Codes and inspections in Washington
| Rule | Who inspects or enforces | How often |
|---|---|---|
| Power boilers | Labor and Industries boiler inspectors | External and internal inspections every year |
| Steam heating boilers | Washington boiler inspectors | Outside and inside every two years |
| Hot water heating boilers | Washington boiler inspectors | Outside every two years; inside every fourth year |
| Elevators, lifts and moving walks | Department of Labor and Industries | Inspected and tested at least once a year |
| State energy code | Enforced statewide, with Washington amendments | 2021 Washington State Energy Code, since March 15, 2024 |
| Clean Buildings Tier 1 | Owners of buildings over 50,000 square feet | First reports due June 1, 2026 to 2028 by size |
| Workplace safety: DOSH | Labor and Industries' Division of Occupational Safety and Health | Most private workplaces in the state |
Rules and funding by type of organization
Asset preservation for state-funded buildings
Districts with state-funded buildings accepted since January 1, 1994 must run an asset preservation program. That means a condition assessment every year, reported by April 1, and an evaluation by a state-approved evaluator every six years.
An energy standard for large buildings
Clean Buildings applies to Tier 1 buildings over 50,000 square feet. Owners must benchmark energy use, run an operations and maintenance program and keep an energy management plan.
Dormitories count toward Tier 1
Dormitory floor area counts toward the Clean Buildings threshold. Campus buildings between 90,000 and 220,000 square feet report by June 1, 2027.
Longer boiler intervals with good records
In an accredited owner-user program, power boiler internal inspections can stretch to seven years. Water treatment must be monitored and inspection, maintenance and treatment records kept.
Find your type of organization
What to do this year
- Set each boiler and water heater on its own cycle: yearly, every two years or every fourth year.Work order management
- Build the operations and maintenance program Clean Buildings asks for from the preventive maintenance plans already running.Preventive maintenance plan
- Score each building's condition every year, so the April board report is ready on time.Facility condition index (FCI) calculator
- Estimate what planned upkeep saves in buildings that must meet an energy target.Preventive maintenance savings calculator
- And much more. Let myFacilities build your custom to-do list, so you can plan, maintain and budget for your facilities with confidence.Book a call
Questions about Facilities Management in Washington
How often are elevators inspected in Washington?
At least once a year. Labor and Industries inspects and tests every conveyance, and an owner can be penalized for not fixing a violation within ninety days of written notice.
When must Washington buildings comply with Clean Buildings?
Tier 1 buildings over 220,000 square feet were due June 1, 2026. Those over 90,000 square feet follow on June 1, 2027, and those over 50,000 on June 1, 2028.
What inspection schedule do Washington boilers follow?
Power boilers: inside and out every year. Steam heating boilers: every two years. Hot water heating boilers: outside every two years and inside every fourth year. Water heaters: an external check every two years.
Every inspection and repair in Washington, planned in one place.
See how inspection dates, preventive maintenance and capital plans work together.