Facility maintenance in Colorado
Colorado inspects power boilers every year and heating boilers every two, registers every elevator and now sets energy targets for large buildings. Start with the rule that hits your buildings first.
Colorado at a glance
- 1,932Public schoolsStatewide
- 272School districtsStatewide
- 59CollegesStatewide
- 50,000sq ftPerformance ruleStatewide
- 156.3daysFreezing nightsDenver area
- 46.2daysAt 90°F or moreDenver area
What Colorado's climate does to buildings
Denver's 1991-2020 normals pair a long freezing season with plenty of hot days and a dry year, while summer storms bring hail and wind.
Denver metro area
A long freezing season
Lows hit 32°F or below on 156.3 days in a normal year, and 6.2 nights drop to 0°F or below. Freeze-protect coils, sprinklers and exposed lines.
Plenty of hot afternoons
Denver averages 46.2 days at 90°F or more. Service rooftop units and evaporative coolers before the heat arrives.
Dry, with a heating tilt
Normal precipitation is just 14.48 inches. Heating degree days (5,862) far outnumber cooling degree days (850), so heating plants carry most of the year.
Storm season on the roof
In 2025 Denver logged thunderstorms on 65 days, hail on 3 and a 70 mph gust on July 10. Walk roofs and rooftop equipment after each storm.
A maintenance year in Colorado
- JanCheck heat tracing and freeze protection after cold snaps
- FebReview boiler certificates in the state database
- MarClose boiler deficiencies within the 45-day window
- AprStart cooling before the first 90°F afternoons
- MayInspect roofs and rooftop units for hail damage
- JunClean condenser coils ahead of peak heat
- JulStart benchmarking when the reporting period opens July 1
- AugSchedule annual elevator and escalator inspections
- SepTest boiler safety controls before heating season
- OctSubmit benchmarking data before the November 1 deadline
- NovBlow out irrigation lines before hard freezes
- DecPlan next year's boiler and water heater inspections
Codes and inspections in Colorado
| Rule | Who inspects or enforces | How often |
|---|---|---|
| Power boilers (ASME Section I) | State or insurance-commissioned inspectors | Internal and external inspections every year |
| Heating boilers (ASME Section IV) | State or insurance-commissioned inspectors | External inspection every 2 years |
| Large water heaters | Owners of units inspected as boilers | Inspected every 2 years |
| Boiler repairs after inspection | Boiler owners | 45 days to comply; extensions on request |
| Elevators, escalators and lifts | Owners, registered with OPS | Annual inspection under state conveyance rules |
| Conveyance injury accidents | Owner or manager | Report within 24 hours of the accident |
| Building Performance Colorado | Owners of covered commercial buildings | Benchmarking report and fee due November 1 yearly |
| Energy code | Each local jurisdiction, under home rule | Adopted and enforced locally |
Rules and funding by type of organization
BEST grants for school buildings
Since 2008, BEST has awarded competitive grants for new schools and for renovating existing building systems. An emergency grant can help when a facility becomes unusable or unsafe, and Facility Insight assesses school buildings statewide.
Performance targets from 50,000 square feet
Most commercial buildings this size benchmark every year, with reports and fees due November 1. State goals call for 7% lower emissions by 2026 and 20% by 2030. Owners can switch their 2030 pathway without extra paperwork until November 1, 2028.
High-pressure boilers need yearly inspections
Power boilers, common in processing plants and commercial laundries, get internal and external inspections every year. Insured boilers are inspected by the insurer's state-commissioned inspector. Tell the state boiler office before a new or relocated boiler goes into service.
Find your type of organization
What to do this year
- Put every power boiler, heating boiler and large water heater on its own inspection cycle.Preventive maintenance plan
- After a hailstorm, log roof and rooftop unit damage as work orders with photos and locations.Writing a useful work order
- Decide whether storm-damaged rooftop equipment is worth repairing or replacing.Repair or replace calculator
- Turn condition data into a capital plan before a grant or budget request.Capital planning
- And much more. Let myFacilities build your custom to-do list, so you can plan, maintain and budget for your facilities with confidence.Book a call
Questions about Facilities Management in Colorado
How often are boilers inspected in Colorado?
Power boilers get internal and external inspections every year. Heating boilers and large water heaters get an external inspection every 2 years. Insured boilers are inspected by the insurer's state-commissioned inspector.
What must a Colorado owner do after an elevator injury accident?
Stop access to the conveyance and report the accident within 24 hours to OPS or the local authority. Then investigate, inspect, repair and re-inspect it. Some cities and counties run their own conveyance programs under OPS delegation.
Do Denver buildings report to both Energize Denver and the state?
Yes. Denver owners in both programs still submit annual benchmarking to the city and to Colorado. Meeting Energize Denver's efficiency requirements counts toward the state's performance targets.
Does Colorado have a statewide energy code?
Colorado is a home rule state, so energy codes are adopted and enforced by each jurisdiction. DOE rates the commercial equivalent as ASHRAE 90.1-2016.
Which water heaters does Colorado inspect as boilers?
Units with heat input of 200,000 BTU/hr or greater, a temperature of 210°F or greater, or 120 gallons or more. Those units get an inspection every 2 years.
Every inspection and repair in Colorado, planned in one place.
See how inspection dates, preventive maintenance and capital plans work together.