Facility maintenance in Texas
Texas buildings face 100°F summers, freezing nights and a long hurricane season.
Texas at a glance
- 20.2daysAt 100°F or moreNorth Texas
- 29.2daysFreezing lowsNorth Texas
- 2,824Cooling deg. daysNorth Texas
- 9,180Public schoolsStatewide
- 1,236School districtsStatewide
- 102Public collegesStatewide
What Texas's climate does to buildings
Cooling carries most of the load in Texas, but winter freezes and hurricane season both need their own plans.
Dallas/Fort Worth and North Texas
Cooling carries the load
At DFW, normal cooling degree days reach 2,824 a year, against 2,220 for heating. Chillers, cooling towers and rooftop units work hardest, so service them before May.
Triple-digit summers
DFW averages 20.2 days a year at 100°F or hotter. Compressors, belts and roof coatings take the strain, so plan replacements by remaining life rather than after failures.
Freezes still arrive
DFW also averages 29.2 days a year with a low of 32°F or below. Insulate exposed piping, test heat tracing and protect backflow preventers before the first cold front.
Across Texas
Hurricane season on the coast
The Atlantic hurricane season runs from June 1 to November 30. Coastal sites should check roof edges, generators and drainage before June, then walk each building after a storm.
A maintenance year in Texas
- JanNorth TexasCheck heat tracing and insulation on exposed pipes
- FebNorth TexasAfter hard freezes, look for split pipes and sprinkler leaks
- MarBook boiler inspections that fall due this year
- AprClean condenser coils and test chiller controls
- MayTest generators before hurricane season opens June 1
- JunCompare summer electric use with the energy plan
- JulCheck cooling tower chemistry and fan motors weekly
- AugInspect roofs and drains after each tropical storm
- SepReview a year of electric use against the goal
- OctService heating plants before the first cold front
- NovHurricane season ends November 30: close out storm repairs
- DecNorth TexasInsulate backflow preventers and outdoor valves
Codes and inspections in Texas
| Rule | Who inspects or enforces | How often |
|---|---|---|
| Power boilers, unfired boilers and process steam generators | Texas Commissioned Boiler Inspectors, under TDLR | Every year |
| Hot water and steam heating boilers | Commissioned boiler inspectors | Every two years |
| Hot water supply boilers and potable water heaters | Commissioned boiler inspectors | Every three years |
| Elevators, escalators and related equipment | The building owner, for each unit | Certificate of Compliance good for one year |
| Commercial energy code | Mandatory statewide | 2015 IECC and ASHRAE 90.1-2013, since November 1, 2016 |
| Safety and security audits | School districts and public junior college districts | At least once every three years |
| Electric use reduction goals | Covered state agencies, universities and political subdivisions | Yearly report to the State Energy Conservation Office |
Rules and funding by type of organization
Every district needs an energy plan
Each district's board must adopt a long-range plan to cut annual electric use by five percent. Strategies are judged on net costs and savings over seven years, so lifetime cost counts, not just first cost.
Electric goals and safety audits
Public universities and colleges set a goal to cut electric use at least five percent each fiscal year and report progress annually. Junior college districts also audit facility safety and security at least every three years.
Five percent a year, reported to the state
Covered cities, counties and other political subdivisions set a goal to cut electric use at least five percent a year. The goal spans seven fiscal years from September 1, 2019. Progress goes to the State Energy Conservation Office yearly.
Annual inspections for process boilers
Power boilers, unfired boilers and process steam generators need an inspection every year from a commissioned inspector. Heating boilers go every two years, and water heaters every three.
Find your type of organization
What to do this year
- Set each boiler's inspection cycle, annual, two-year or three-year, as a recurring task with the inspector's report attached.Features
- Track electric use by building, so progress toward a five percent goal is ready for the yearly report.How myFacilities works for local government
- Before summer, estimate how much life chillers and rooftop units have left at every site.Equipment life expectancy calculator
- After a hard freeze, compare repairing and replacing damaged equipment before the next budget.Repair or replace calculator
- And much more. Let myFacilities build your custom to-do list, so you can plan, maintain and budget for your facilities with confidence.Book a call
Questions about Facilities Management in Texas
Which Texas boilers need an inspection every year?
Power boilers, unfired boilers and process steam generators. Hot water and steam heating boilers go every two years, and hot water supply boilers and potable water heaters every three.
Who is responsible for elevator certificates in Texas?
The building owner. Each elevator or escalator needs its own Certificate of Compliance, good for one year. The signed inspection report goes to TDLR by the 30th day after the inspection.
Which energy code applies to commercial buildings in Texas?
The 2015 International Energy Conservation Code and ASHRAE 90.1-2013, enforced statewide since November 1, 2016, according to the U.S. Department of Energy.
When is hurricane season on the Texas coast?
The Atlantic season runs from June 1 to November 30. An average Atlantic season brings 14 named storms and 7 hurricanes, so coastal sites check generators, roofs and drainage before June.