Facility maintenance in Missouri
Missouri issues about 25,000 boiler certificates a year, inspects elevators annually and leaves energy codes to local governments. Borrowing votes need four-sevenths or two-thirds.
Missouri at a glance
- 2,473Public schoolsStatewide
- 565School districtsStatewide
- 27Public collegesStatewide
- 25,000Certificates/yrStatewide
- 87.9°FSummer highSt. Louis
- 41.70inPrecipitationSt. Louis
What Missouri's climate does to buildings
St. Louis normals show humid summers, a wet spring and freezing winter nights. Cooling, drainage and freeze protection each need a turn on the calendar.
St. Louis and eastern Missouri
Humid summer nights
Summer highs average 87.9°F and lows hold near 69.2°F, so cooling equipment gets little rest overnight. Check condensate drains and cooling tower water treatment by June.
Spring brings the most rain
Of 41.70 inches of yearly precipitation, 13.05 inches falls in spring. Clear roof drains, gutters and area drains in March, and test sump pumps.
Freezing nights, modest snow
Winter lows average 26.6°F and snowfall totals 16.6 inches. Protect sprinkler risers and outdoor valves, and keep ice melt stocked at entrances.
A maintenance year in Missouri
- JanProtect sprinkler risers and outdoor valves from freezing
- FebList boiler certificates that expire this year
- MarClear roof drains and gutters before spring rains
- AprBook ride and climbing wall inspections before summer
- MayTest sump pumps and area drains after heavy storms
- JunTreat cooling tower water and clear condensate drains
- JulWatch chiller loads through warm, humid nights
- AugSchedule elevator inspections with a licensed inspector and mechanic
- SepReview capital needs ahead of spring bond elections
- OctStart boilers and test low-water cutoffs
- NovPost current inspection certificates in mechanical rooms
- DecStock ice melt for entrances and walks
Codes and inspections in Missouri
| Rule | Who inspects or enforces | How often |
|---|---|---|
| Boilers and pressure vessels | Division of Fire Safety, or the insurer's inspector | Every one to two years, by use |
| Running without a valid certificate | Class A misdemeanor | Fines up to $10,000 per day, per object |
| New boiler installations | Division of Fire Safety | Permit before installation begins |
| Elevators | State-licensed inspector with a licensed mechanic | Every year |
| Elevator code | Elevator Safety Board | ASME A17.1-2016 plus state minimum standards |
| Energy code | Each city or county (home rule) | No statewide edition |
| Fire safety in care facilities | Division of Fire Safety inspection unit | Checked against state rules and NFPA standards |
| Amusement rides | State-approved ride inspector | Within the last 12 months, plus spot checks |
Rules and funding by type of organization
Bond votes and the debt ceiling
Districts may borrow up to fifteen percent of taxable tangible property by popular vote. Approval takes four-sevenths at general municipal, primary or general elections, and two-thirds at any other election.
Certificate of need thresholds
Major medical equipment over $1,000,000 needs a certificate of need. So do long-term care bed projects of $600,000 or more. The review committee meets about every eight weeks.
Climbing walls, slides and pool heaters
Climbing walls over 10 feet and dry slides over 20 feet count as rides, each needing a passed inspection within 12 months. Pool heaters over 200,000 Btu/hr fall under the boiler law.
Local energy codes and borrowing limits
Cities and counties choose their own energy codes. By popular vote they may borrow up to five percent of taxable tangible property.
Compressor tanks are pressure vessels
Air compressor tanks over 10 cubic feet or 200 psi need inspection certificates. Running one without a valid certificate risks fines of $10,000 per day.
Find your type of organization
What to do this year
- List every boiler, water heater and pool heater over 200,000 Btu/hr with its certificate date and inspector.Recurring inspections
- Before a bond or capital vote, rank needs by condition and cost so the plan holds up to questions.Presenting a capital plan
- Set spring drain and sump pump checks for every site before the wettest months.Preventive maintenance plan
- Weigh repair against replacement for aging chillers and boilers before the next capital request.Repair or replace calculator
- And much more. Let myFacilities build your custom to-do list, so you can plan, maintain and budget for your facilities with confidence.Book a call
Questions about Facilities Management in Missouri
How often must Missouri boilers and pressure vessels be inspected?
Every one to two years, depending on use, and most objects every two years. Steam boilers above 15 psi also need an internal water-side inspection every two years.
What happens if a Missouri boiler runs without a valid certificate?
It is a Class A misdemeanor. Fines can reach $10,000 per day for each object, and the state issues about 25,000 certificates a year.
How often are elevators inspected in Missouri?
Every year, by a state-licensed inspector working with a licensed elevator mechanic. Owners then get 120 days to correct any violations found.
What vote do Missouri school districts, cities and counties need to borrow?
Four-sevenths at general municipal, primary or general elections, and two-thirds at other elections. School districts may borrow up to fifteen percent of taxable tangible property; cities and counties five percent.
Does Missouri have a statewide energy code?
No. DOE lists Missouri as home rule for both residential and commercial buildings, so each jurisdiction adopts and enforces its own.