Skip to content
Menu

Preventive maintenance for colleges and universities

A preventive maintenance plan for colleges that follows the academic calendar

On a campus, the calendar decides when work can happen. A preventive maintenance plan that knows when terms start, when halls empty and when labs can pause for testing keeps buildings ready for students and stops the backlog from growing.

  • For colleges and universities
  • About 6 min read

In short

  • Preventive maintenance at a college or university covers something close to a small city: residence halls, classrooms, research labs, athletics, dining and the central plant that heats and cools them.
  • The academic calendar sets the windows. Shutdowns and room entries move to breaks and summer, while quick checks continue through the term in occupied buildings.
  • In myFacilities, plans open work orders when they come due, technicians log readings on a phone, and each completed task adds to the asset history behind condition reviews and capital plans.

Why a campus plan runs on the academic calendar

A campus is many building types under one owner. A residence hall behaves like an apartment block, a research lab like a small industrial site, an arena like an event venue, and the central plant like a utility. Each has its own equipment and its own quiet hours, and the institution answers for all of them.

The calendar ties them together. Move-in week fills every residence hall at once. Fall and spring terms put lecture halls and labs under heavy use. Winter break, spring break and summer open short windows for shutdowns, although summer conferences, camps and research that never pauses often claim those weeks too.

Deferred work also shows up in a number leadership watches. APPA, the association for educational facilities professionals, defines the facilities condition index (FCI) as the cost of the deferred maintenance backlog divided by the current replacement value of the buildings. Equipment that fails early adds to that backlog, so a steady preventive maintenance plan is one of the few levers that slows the ratio from climbing.

Building a plan around terms, breaks and summers

  1. Map the calendar firstMark move-in and move-out, the start and end of each term, finals, breaks, commencement and summer conference dates. Every plan you write afterwards will point to one of these windows.
  2. Inventory by building typeGroup assets the way the campus runs: residence halls, academic buildings, research labs, athletics and recreation, dining, and the central plant with its steam or hot water distribution, chillers and cooling towers.
  3. Give labs their own trackFume hoods, lab exhaust fans and room pressure controls protect researchers. Many institutions check each hood's face velocity and alarm at least once a year, run a containment test such as ASHRAE 110 when a hood is installed or changed, and agree each test date with the lab manager.
  4. Book the summer in the springBoiler inspections, cooling tower cleaning, residence hall room turnover and roof repairs all compete for the same few weeks. Schedule them before conference bookings fill the halls.
  5. Keep term-time checks short and steadyFilter changes, belt checks, emergency lighting tests, elevator checks and steam trap surveys can continue while classes run, as long as they avoid lectures and exams.
  6. Report against staffingCompare scheduled hours with the technicians you have. APPA's operational guidelines describe five levels of maintenance, custodial and grounds service tied to staffing, which helps explain to leadership what the current team can sustain.

What myFacilities does for a campus plan

Schedules tied to the term

Set a plan on one asset or a whole group, such as every residence hall boiler, and pick the month it runs. myFacilities opens the work orders on that date and routes them to the shop that owns them.

Lab checks on a phone

A technician at a fume hood records face velocity, the alarm test and sash position on a phone. If a basement lab has no signal, the entries upload once the phone reconnects.

A record for each building

Completed tasks stay on the asset with dates, names, readings and photos, so the next technician, auditor or lab safety officer sees the full story.

Overdue across the campus

The Preventive Maintenance list applies one overdue rule to every building, so a missed check in a distant residence hall sits right next to one on the main quad.

That history also guides capital decisions. When the same chiller needs repairs every August, an iFCA™ condition review and its work history feed SMART™ capital planning, and its replacement can be timed for a break instead of the first warm week of fall term.

An example from one residence hall system. The figures below show how quickly a plan grows. They are an example, not an APPA benchmark; your own frequencies come from the manufacturer and your engineers.

  • Residence halls on campus12
  • Fan coil units per hall (average)150
  • Fan coil units in all halls (12 × 150)1,800
  • Filter changes a year at 3 per unit (1,800 × 3)5,400
  • Coil and drain pan cleanings, once a year in summer (1,800 × 1)1,800
  • Tasks a year for residence hall fan coils alone7,200

The summer share, 1,800 cleanings in roughly ten weeks, comes to about 180 a week before the first conference group arrives. A figure like that tells you whether to hire summer help or spread the cleanings across winter and spring breaks.

Try the tools

Start with the central plant and research labs

Pick the systems where a failure affects the most people. On most campuses that means the central plant and steam distribution, fume hoods and lab exhaust, fire and life safety systems, and residence hall heating. Academic buildings and athletics can follow in the next round.

Bring your current spreadsheet in with column matching rather than retyping it. Then print QR labels for mechanical rooms and lab equipment, so a technician can scan a fan or a hood and see its plan, its last readings and any open work before starting.

Questions campus teams ask us

Short answers about preventive maintenance at colleges and universities.

How do we fit preventive maintenance around classes and exams?

Treat the academic calendar as an input to every schedule. Put shutdowns, noisy work and room entries into breaks and summer, and keep quick checks that need no shutdown in term time. In myFacilities each plan has its own schedule, so a residence hall plan can run in June while a classroom building plan runs over winter break.

Should research labs have a separate plan?

In most cases, yes. Fume hoods, biosafety cabinets and lab exhaust carry real risks for the people using them, and their tests often need the lab's agreement and a record the environmental health and safety office can review. Separate plans make those records easy to find.

How does preventive maintenance affect our facility condition index?

Indirectly but steadily. FCI rises when deferred maintenance grows faster than replacement value. Equipment serviced on schedule tends to reach its expected life instead of failing early, which keeps surprise repairs out of the backlog.

Who outside facilities should see the plan?

Housing, athletics, research administration and the budget office each care about different buildings. Share completion rates and overdue work for their spaces, and bring condition and history data to capital planning meetings so requests rest on records.

More for campus facilities teams

Guides and tools for colleges and universities.

Keep every building ready for the next term and the plan on track.

See how term-aware plans, phone checklists and a campus-wide overdue list work for your institution.